This guide will allow you to prepare, setup and configure the Nebula Ice Bath for the first time after installation or moving it to a different location.
Step 1 - Position the Nebula Ice Bath ensuring the back of the bath has a minimum distance from a wall of 25cm.
Step 2 - The right-hand side of the bath should have enough distance for access for maintenance, which is generally 40-50cm
Step 3 - The left-hand side of the bath can be positioned up against a wall
Step 4 - When correctly positioned, attach a hose to the nearest filling point. This could be a garden tap, under kitchen sink tap or under bathroom sink taps
Note, you can use the supplied Nebula Hose Attachment to connect to a normal quick connect male hose attachment (usually found in gardens)
If no garden quick connect male connection is nearby, you can unscrew the Nebula Hose Attachment fitting and screw this onto a water connection under a sink or in a bathroom
If this is not possible, you may have to use a normal garden hose without an attachment and push this over a kitchen or bathroom tap. Ensure it is secure
Step 5 - Position the exit side of the hose into the Nebula Ice Bath Tub,
Step 6 - Turn on the water tap and start filling the bath with a hose until the bath is filled 4-5cm above the top water exit hole
Step 7 - Using the supplied 3 meter cable and plug, plug the Nebula Ice Bath into a 3-pin socket
If using extension cables, ensure the cable is fully wound out, otherwise the extension cable will over-heat
Step 6 - Switch on the wall socket
Step 7 - The Nebula Ice Bath will now power up and the display will switch on
Note: this only powers up the Nebula Ice Bath, it does not turn the bath ON yet
Setting the bath MODE:
- Before turning the bath on, a MODE should selected depending on requirements.
- On the Homepage, Press the DOWN/UP button until the SET menu icon is displayed
- Press ENTER
- Press ENTER again and change SETPOINT UP/DOWN
- Press ENTER to confirm the SETPOINT and move to MODE
- Press UP or DOWN to scroll through different MODES
- Press ENTER to confirm the MODE
- Press BACK to return to HOMEPAGE
Turning the Nebula Ice Bath ON:
- When the desired MODE is selected, Press BACK to go to the HOMEPAGE.
- Press the DOWN/UP button until the POWER icon is displayed as shown below
- Press ENTER to enter the POWER menu
- Press ENTER again to highlight the ON/OFF button
- Press UP or DOWN until ON is shown. This will turn the bath ON
- Turning the bath ON starts the bath in the currently selected mode in the SET menu
Note: Pressing UP/DOWN again will immediately switch between ON/OFF
- If ON is shown, the bath is ON in its active mode
- If OFF is shown, the bath is completely OFF